GDB-H Gacmo Toos ah oo Toos ah oo Gacanta lagu Hayo ayaa rogta Tijaabada saamiga
GDB-H waa qalab gacanta lagu hayo.Waxay si sax ah u cabbiri kartaa saamiga leexashada, kooxda iyo xagasha wejiga, taas oo ku habboon dhammaan noocyada kala duwan ee Transformers sida Transformers-ka nooca Z, Transformers rectifier, Transformers foornooyinka korontada, Transformers-ka beddelka wejiga, transformers-ka jiidashada, Scot iyo beddelka-scott-scott.
●5.6inch TFT midabka LCD, si dareen leh u soo bandhigay xogta iyo jaantuska vector.
●3-tijaabada wajiga isku mar.Gelida tamarta wejiga kaliya, oo leh isugaynta dhijitaalka gudeed isha tijaabada mawjadda sine.Waxay soo saartaa awoodda tijaabada 3-waji (degree qalloocadu waxay ka yar tahay 0.1%, heerka summetry ayaa ka wanaagsan 0.05%) by cod-weyneeye awooda Hi-fi.Natiijooyinka imtixaanku waxay leeyihiin u dhigma ka sii wanaagsan, mana u muuqan doonto go'aan-doorasho.
●Labada cabbir hal weji iyo tijaabo toos ah oo 3-waji ah.Waxay cabbiri kartaa polarity iyo xagasha wejiga ee hal weji ama imtixaan 3-waji ah.Hal mar dhammaystir cabbirka saamiga leexashada, qiimaha xagasha wajiga, khaladka, booska tuubada, qiimaha tuubada AB, BC, CA.Nambarka kooxda si toos ah ayaa loo aqoonsan karaa.
●Hawlaha cabbirka xagasha wajiga.Si sax ah u cabbir xagal wejiga u dhexeeya danab sare iyo danab hoose.Waxa kale oo ay cabbiri kartaa saamiga leexashada iyo xagasha transformers-ka "Non-integral point"
●Natiijooyinka tijaabada waxaa lagu soo bandhigay jaantus iyo vector lix geesood ah, waxay si toos ah u muujinayaan kooxda isku xirka beddelka.
●Looma baahna in la doorto habka isku xirka ama kooxda isku xirka, waxay cabbiri kartaa Y/△, △/Y transformer iyada oo aan lahayn xidhiidh gaaban oo dibadda ah.Waxa kale oo ay bedeli kartaa dariiqooyinka isku xidhka iyada oo loo eegayo shayada tijaabada ee la doortay.Transformer-ka aan lahayn taarikada magaca waa la cabbiri karaa.
●Si degdeg ah u cabbir saamiga leexashada iyo khaladka saamiga ee booska beddelaha tuubada kasta.Kaliya geli saamiga la qiimeeyay hal mar, looma baahna soo gelinta soo noqnoqda si loo xisaabiyo khaladka saamiga boos kasta oo taabasho ah.
●Iyada oo leh hawlaha cabbiraadda saamiga leexashada iyo cabbirka saamiga tamarta shaqada.Saamiga hawlgalka ayaa si dhab ah u muujin kara qiimaha dhabta ah ee saamiga danab inta lagu jiro hawlgalka.
●Iyada oo iska caabin gariir wanaagsan leh.
●Isha tijaabadu ee qalabkani waa il-wave seerka caadiga ah ee isku xidhka dhijitaalka ah.Darajada qallooca ayaa ka yar 0.1%, oo aan saameyn ku yeelan tayada sahayda korontada.
●Cabbir yar, miisaan fudud, fudud in la qaado.
●Ku-dhismay baytari lithium-ion ah oo awood sare leh oo dib loo dallaci karo.Imtixaanka waxaa lagu dhamayn karaa awood la'aan.Dallacaadda buuxda ee hal mar ah waxay qaadataa in ka badan 800 jeer cabbir joogto ah.
●Xogta cabbirka goobta waa la keydin karaa, natiijadana waxaa lagu wareejin karaa PC by U disk.
●Qiyaasta TTR: 0.8 ~ 10000.
●Xawaaraha cabbiraadda degdegga ah: Imtixaan saddex-waji ah ayaa lagu dhammeyn karaa 60 ilbiriqsi gudahood.
●Saxnaanta cabbirka:
Saxnaanta cabbiraadda korantada ee dhinaca HV: 0.05%
Saxnaanta cabbiraadda korantada ee dhinaca LV: 0.1%
Saxnaanta cabbirka xagasha wejiga: 0.1°
Saxnaanta cabbirka TTR: 0.1% (0.8-3000)
0.2% (3000-10000)
●Miisaanka: qiyaastii 3Kg.
Qalabka GDB-H | 1pc |
Kiis dheeri ah | 1pc |
Tijaabada rasaasta HV oo leh xajin | 1set |
Tijaabada Ledhka LV oo leh xajin | 1set |
Fuse | 2pcs |
Dameeraha | 1pc |
Tilmaamaha isticmaalaha | 1pc |
Warbixinta tijaabada warshadda | 1pc |